Ro -500reverse osmosis machine adopt advanced one stage lower pressure reverse osmosis technology to purify running water. It can get rid of harmful material, such as bacteria, remanded and heave metal ion with the filter and absorb system, these system can ales delete an monogenic virus, such as , if wanted to use this machine to purify water, you should notice the water quality first and must accord to the instruction to operate, to maintain and keep. The conductivity of water had made should fewer than 10 us per cm. make sure that the immediacy water correspond the document attachment demand and the hygiene standard of life water.
RO-500 reverse osmosis machine integrate the water –made technology together, tank drenched clean flow and easily maintained .it is considered as the nuclear equipment in water factory, in community and oil area. It ales can be used in food, drink, chemical hospital and electronically field.
The quality of purify water should under conform the GB5749-85 the hygiene standard of life water, and the conductivity of water should under 500usper cm,
The outside water should conform to the 19th hygiene document in ministry of hygiene.
2 The main parameter
ITEM |
PAEAMETR |
NOTE |
Electric resource |
~380/220v 50HZ |
|
Rating current |
6A/12A |
|
Rating work pressure |
1.0~1.2MPa |
|
Raw water pressure ,flux |
≧0.15MPa ≧1.5T/H |
|
Quantity of product water |
≧500L/H |
25℃ below under 1.2MPa |
The power of high pressure |
0.75KW |
BJZ-100 |
Multi-pump power |
1.5KW/380V |
SMP2_130 |
The period of the equipment
1 quarts filter
When working accumulated more than the 8 hours, it should be reverse circulation about 15 minutes
When working accumulated more than the 2900 hours, the quartz filter material should be changed.
2 the carbon absorb filter
When the residual chlorine﹥0.1mg/L, the filter material should be changed .
When working accumulated more than 720 hours, the carbon filter material should also be changed.
3 ultra- flirtation filter
Usually, the filing element should be changed when working accumulated more than 720 hours.
The filing element should be changed when the outside pressure under 0.04MPand when the water dictator is light in the panel.
4 reverse osmosis filter
The RO membrane should be washed with the medicament, when working accumulating more than 240 hours.
The membrane should be changed, when working accumulating more than 2900 hours,
Especially, make sure that the ground wives should connect with ground.
㈢The operation instruction of pre treatment
1the operation instruction of the Dual media filter
A .the machine should install a proper place ,and unload the head of manual drive on top of filter .and fill the course and slender quartz from down to up .and then screw down the manual drive head on the machine ,
B. Get through the electric resource and water resource,
C .when work in common, the valve V1 and V3 should be open, and all of others are closed, then the water poured in.
D the step of reverse circulation about the media dual filter :(the better is one time a day )
E Common washing step:( had better to do after reverse circulation ) the V1 , V3 V14 should open, and make sure that all the other valve is closed.
F the quartz should be packed in naked to make sure the filtration effect.
2 The operation instruction of carbon filter.